Acoustic consultancy services, from concept to completion

From the first sketch to post-completion testing, we help architects and interior designers make spaces sound as considered as they look.


Architectural acoustics: office with sculptural wall panel and timber ceiling baffles

Intro
Advice across the full design process — from early concept input through detailed specification, predictive modelling and post-completion verification. We treat room acoustics, sound insulation and material selection as integral parts of the design.

How it works

  • Review of drawings and design intent at concept and developed design stages

  • Recommendations on room shapes, finishes and constructions

  • Predictive modelling of reverberation time, speech intelligibility and sound insulation

  • Specification of constructions and materials

  • Site inspections and post-completion testing where required

Standards & regulations
Building Regulations Approved Document E (England), BS 8233, ISO 3382, BB93 (schools), HTM 08-01 (healthcare).

Environmental noise: stone building facade and entrance with planter

Intro
Assessment and mitigation of external noise — road, rail, aircraft and industrial — so that planning, design and occupant comfort are properly resolved.

How it works

  • Baseline noise surveys

  • Prediction of future noise levels using recognised calculation methods

  • Assessment against relevant criteria

  • Design of mitigation (barriers, façade upgrades, ventilation strategies)

  • Reporting for planning applications

Standards & regulations
BS 8233, ProPG (planning and noise), BS 4142 (industrial/commercial), WHO Environmental Noise Guidelines, local authority requirements.

Building services noise: exposed pipework and plant behind planting

Intro
Control of noise and vibration from plant, services and building systems. Strategic advice on location, enclosure design and transmission paths so that mechanical systems do not compromise the finished space.

How it works

  • Review of plant schedules and layouts

  • Prediction of noise break-out and break-in

  • Advice on anti-vibration mounts, enclosures and duct attenuators

  • Coordination with MEP consultants

  • Commissioning measurements where required

Standards & regulations
BS 8233, CIBSE guides, manufacturer data, project-specific criteria (often NR or dBA limits).

Acoustic modelling: tablet showing room model and plan drawings

Intro
Use of advanced modelling tools to predict room acoustics, noise break-in and break-out, and to test design options before they are fixed.

How it works

  • Import of architectural models or construction of simplified geometry

  • Assignment of material absorption and scattering data

  • Simulation of reverberation time, speech transmission index, noise levels

  • Iteration of design options with the design team

  • Clear reporting of results and recommendations

Standards & regulations
ISO 3382, ISO 3382-3 (open-plan offices), BB93, project-specific targets.

Vibration: close-up of window frame junction in a concrete wall

Intro
Advice on the control of structure-borne and ground-borne vibration, including subjective response and isolation strategies for sensitive spaces.

How it works

  • Vibration surveys (existing or predicted)

  • Assessment against criteria for human response or sensitive equipment

  • Design of isolation (floating floors, building isolation, equipment mounts)

  • Coordination with structural engineers

Standards & regulations
BS 6472 (human response to vibration), BS 5228, VC curves or manufacturer limits for sensitive equipment.

Measurement and testing: sound level meter with microphone on stone

Intro
On-site measurement of noise, vibration and room acoustic parameters using calibrated instrumentation, with clear reporting that designers can act on.

How it works

  • Pre- and post-completion testing

  • Sound insulation (airborne and impact)

  • Reverberation time and background noise

  • Plant noise and vibration

  • Fully calibrated Class 1 equipment and traceable reporting

Standards & regulations
ISO 16283 / ISO 140 series (sound insulation), ISO 3382 (room acoustics), BS 4142, Building Regulations Part E testing requirements.

Planning and expert advice: floor plan drawing, notebook and pen

Intro
Technical input and evidence for planning applications, noise nuisance cases and licensing. Clear, defensible documentation that supports the regulatory process.

How it works

  • Noise impact assessments

  • Expert reports for planning or appeals

  • Liaison with local authorities and environmental health

  • Attendance at meetings or hearings where required

Standards & regulations
National Planning Policy Framework (NPPF), ProPG, BS 4142, BS 8233, local authority technical guidance.

Sustainable acoustic design: calm living space with natural materials

Intro
Integration of acoustic performance with wider sustainability goals, including material choices and credit achievement under BREEAM, LEED and similar frameworks.

How it works

  • Early advice on acoustic credits and targets

  • Material recommendations that balance acoustic performance with embodied carbon and recyclability

  • Evidence and calculations for assessment submission

  • Coordination with sustainability consultants

Standards & regulations
BREEAM Hea 05 / Pol 05, LEED acoustic credits, WELL Building Standard, relevant national building regulations.

Design to acoustic test: sound level meter beside drawings

Intro
Translation of an existing acoustic report or set of performance criteria into a resolved spatial and material design. We take the numbers and turn them into a buildable, design-led solution.

How it works

  • Review of the source report or criteria

  • Development of room finishes, constructions and details that meet the targets

  • Coordination with the architect and interior designer

  • Optional verification modelling or testing

Standards & regulations
Whatever criteria are set in the original report (commonly Building Regulations Part E, BB93, BS 8233, or client-specific targets).

Product acoustic verification: acoustic material samples beside sound level meter

Intro
Independent checking of the acoustic performance data for products proposed on a project, confirming they meet the required criteria and are suitable for the intended application.

How it works

  • Review of manufacturer test reports and data sheets

  • Comparison against project specification

  • Advice on suitability, installation sensitivity and any gaps in data

  • Clear written confirmation or recommended alternatives

Standards & regulations
ISO 354 (absorption), ISO 10140 / ISO 717 (sound insulation), ASTM equivalents, project specification.

Statement product design: sculptural folded acoustic pendant

Intro
Design of one-off or limited acoustic products and elements for specialist or high-design projects, where standard market solutions are insufficient.

How it works

  • Brief development with the design team

  • Concept design of the acoustic element (form, material, performance)

  • Detailed design and performance prediction

  • Liaison with fabricators and, where needed, prototype testing

Standards & regulations
Performance targets set by the project (ISO 354, ISO 3382, etc.) plus any relevant product safety or fire standards.

Pricing and value engineering: acoustics specification document and drawings

Intro
Review of contractor quotations and specifications to confirm that acoustic items are correctly priced, fully compliant with the design intent, and not over- or under-specified.

How it works

  • Review of tender returns against the acoustic specification

  • Identification of omissions, substitutions or pricing anomalies

  • Advice on acceptable alternatives that maintain performance

  • Clear reporting to the design team or client

Standards & regulations
The project acoustic specification and the standards referenced within it (Part E, BB93, BS 8233, etc.).

Discreet sound system integrated into a design-led interior

Design, specification and commissioning of sound systems that support how a space is used, without visual or acoustic compromise.

Discuss your project

Tell us a little about the space and the stage the design is at, and we will reply from the studio best placed to help.